Part number
Manufacturer
Description
Stock
141
A05722
SALTEK
surge protection with RFI filter, installation close to protected equipment / 16 A, remote fault signalling / T3 (ČSN EN 61643-11 ed.2) 275 10
In Stock
142
A05723
surge protection with RFI filter, installation close to protected equipment / 6 A, power supply interruption / T3 (ČSN EN 61643-11 ed.2) 275 10
143
A05724
surge protection with RFI filter, installation close to protected equipment / 10 A, power supply interruption / T3 (ČSN EN 61643-11 ed.2) 275 10
144
A05725
surge protection with RFI filter, installation close to protected equipment / 16 A, power supply interruption / T3 (ČSN EN 61643-11 ed.2) 275 10
145
A05770
surge protection for TN and TT systems, installation close to protected equipment / 25 A, serially connected / T3 (ČSN EN 61643-11 ed.2) 275 10
146
A05771
surge protection for TN and TT systems, installation close to protected equipment / 25 A, serially connected, remote fault signalling / T3 (ČSN EN 61643-11 ed.2) 275 10
147
A05821
lightning current arrester for telecommunication and signalling lines, installation at the entry into building / max. 70 V / D1, C2 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
148
A05822
lightning current arrester for telecommunication and signalling lines, installation at the entry into building / max. 180 V / D1, C2 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
149
A05834
combination of lightning current and surge arrester for systems TN and TT, installation at the entry into building / up to 150 V AC, 25 kA (10/350 µs), 60 kA (8/20 µs) / T1,T2 (ČSN EN 61643-11 ed.2) 150 25 30
150
A05835
combination of lightning current and surge arrester for systems TN and TT, installation at the entry into building / up to 150 V AC, 25 kA (10/350 µs), 60 kA (8/20 µs), remote fault signalling / T1,T2 (ČSN EN 61643-11 ed.2) 150 30
151
A05957
module with surge protection for additional installation, installation close to protected equipment / acoustic fault signalling / T3 (ČSN EN 61643-11 ed.2)
152
A05958
universal module with surge protection for additional installation, installation close to protected equipment / acoustic fault signalling / T3 (ČSN EN 61643-11 ed.2) 275
153
A05959
universal module with surge protection for additional installation, installation close to protected equipment / remote fault signalling / T3 (ČSN EN 61643-11 ed.2) 275
154
A06036
surge arrester for PV systems (both poles) / up to 1500 V DC, 40 kA (8/20 µs) / PV T2 (ČSN EN 50539-11)
155
A06037
surge arrester for PV systems (both poles) / up to 1500 V DC, 40 kA (8/20 µs), remote fault signalling / PV T2 (ČSN EN 50539-11)
156
A06057
surge protection for 2-core signalling networks, installation close to protected equipment, screwless terminal block / 6 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
157
A06058
surge protection for 2-core signalling networks, installation close to protected equipment, screwless terminal block / 12 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
158
A06059
surge protection for 2-core signalling networks, installation close to protected equipment, screwless terminal block / 24 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
159
A06060
surge protection for 2-core signalling networks, installation close to protected equipment, screwless terminal block / 48 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
160
A06061
surge protection for 2-core floating signalling networks, installation close to protected equipment, screwless terminal block / 6 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012