Part number
Manufacturer
Description
Stock
161
A06062
SALTEK
surge protection for 2-core floating signalling networks, installation close to protected equipment, screwless terminal block / 24 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
In Stock
162
A06063
surge protection for 2-core floating signalling networks, installation close to protected equipment, screwless terminal block / 48 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
163
A06064
surge protection for 2-core high-speed floating signalling lines, installation close to protected equipment, screwless terminal block / 6 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
164
A06065
surge protection for two 1-core signalling networks, installation close to protected equipment, screwless terminal block / 12 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
165
A06066
surge protection for two 1-core signalling networks, installation close to protected equipment, screwless terminal block / 24 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
166
A06067
surge protection for two 1-core signalling networks, installation close to protected equipment, screwless terminal block / 48 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
167
A06069
surge protection for low-frequency 2-core signalling networks, installation close to protected equipment, screwless terminal block / 24 V DC, max. 0.1 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
168
A06070
coarse single stage surge arrester – Gas Discharge Tube, screwless terminal / 70 V / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
169
A06076
varistor surge arrester, suitable for 3-phase TN and IT systems with non-sinusoidal voltage / 690 V DC, 40 kA (8/20) / T2 EN 61643-11:2012, IEC 61643-11:2011
170
A06094
surge protection for TN and TT systems, installation close to protected equipment / 25 A, up to 75 V AC / T3 EN 61643-11:2012, IEC 61643-11:2011
171
A06095
surge protection for TN and TT systems, installation close to protected equipment / 25 A, up to 150 V AC / T3 EN 61643-11:2012, IEC 61643-11:2011
172
A06145
lightning current arrester and surge arrester for PV systems / up to 560 V DC, 25 kA (10/350 µs) / PV T1, PV T2 (ČSN EN 50539-11)
173
A06146
lightning current arrester and surge arrester for PV systems / up to 560 V DC, 25 kA (10/350 µs), remote fault signalling / PV T1, PV T2 (ČSN EN 50539-11)
174
A06290
coarse and fine surge protection of 2-core high-speed signalling lines, installation close to protected device, screwless terminals / 15 V DC, up to 0,5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
175
A06305
varistor surge arrester, suitable for 3-phase TN and IT systems with non-sinusoidal voltage / 690 V DC, 40 kA (8/20), remote fault signalling / T2 EN 61643-11:2012, IEC 61643-11:2011
176
A06385
lightning current arrester with coarse and fine surge protection for 2/3-core signalling lines, installation at the line entry into building and also installation close to protected device / 6 V DC, max. 2 A, replacement module, line separated from protective earth via GDT / D1, C2 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
177
A06388
lightning current arrester with coarse and fine surge protection for two 2-core, installation at the line entry into building and also installation close to protected device / 6 V DC, max. 1 A, replacement module, line separated from protective earth via GDT / D1, C2 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
178
A06390
lightning current arrester with coarse and fine surge protection for two 1-core signalling lines, installation at the line entry into building and also installation close to protected device / 6 V DC, max. 1 A, replacement module, line separated from protective earth via GDT / D1, C2 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
179
A06391
lightning current arrester with coarse and fine surge protection for two 1-core signalling lines, installation at the line entry into building and also installation close to protected device / 6 V DC, max. 2 A, replacement module, line separated from protective earth via GDT / D1, C2 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
180
A06396
lightning current arrester with coarse and fine surge protection for four 1-core signalling lines, installation at the line entry into building and also installation close to protected device / 6 V DC, max. 1 A, replacement module, line separated from protective earth via GDT / D1, C2 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012