Part number
Manufacturer
Description
Stock
101
A05135
SALTEK
surge protection for 2-core floating signalling networks, installation close to protected equipment, terminal block with screw terminals / 48 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
In Stock
102
A05136
surge protection for 2-core floating signalling networks, installation close to protected equipment, terminal block with screw terminals / 60 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
103
A05138
surge protection for 2-core high-speed floating signalling lines, installation close to protected equipment, terminal block with screw terminals / 6 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
104
A05139
surge protection for 2-core high-speed floating signalling lines, installation close to protected equipment, terminal block with screw terminals / 15 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
105
A05140
surge protection for 2-core signalling networks, installation close to protected equipment, terminal block with screw terminals / 6 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
106
A05141
surge protection for 2-core signalling networks, installation close to protected equipment, terminal block with screw terminals / 12 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
107
A05142
surge protection for 2-core signalling networks, installation close to protected equipment, terminal block with screw terminals / 24 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
108
A05143
surge protection for 2-core signalling networks, installation close to protected equipment, terminal block with screw terminals / 48 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
109
A05144
surge protection for two 1-core signalling networks, installation close to protected equipment, terminal block with screw terminals / 12 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
110
A05145
surge protection for two 1-core signalling networks, installation close to protected equipment, terminal block with screw terminals / 24 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
111
A05146
surge protection for two 1-core signalling networks, installation close to protected equipment, terminal block with screw terminals / 60 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
112
A05148
coarse single stage surge arrester – Gas Discharge Tube, screw terminal / 70 V / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
113
A05149
coarse single stage surge arrester – Gas Discharge Tube, screw terminal / 180 V / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
114
A05151
fine single stage surge protection – Varistor, screw terminal / 180 V DC / C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
115
A05153
fine single stage surge protection – fast Suppressor Diod, screw terminal / 24 V DC / C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
116
A05182
lightning current and surge arrester for single-phase system TN-S, installation at the entry into building / 25 kA (10/350 µs), 120 kA (8/20 µs), remote fault signalling / T1,T2 (ČSN EN 61643-11 ed.2)
117
A05183
surge arrester for single-phase system TN-S / 80 kA (8/20 µs), remote fault signalling / T2 (ČSN EN 61643-11 ed.2) 275 20
118
A05185
surge arrester for TN and TT systems / up to 150 V AC, 40 kA (8/20 µs) / T2 (ČSN EN 61643-11 ed.2) 150 15
119
A05186
surge arrester for TN and TT systems / up to 150 V AC, 40 kA (8/20 µs), remote fault signalling / T2 (ČSN EN 61643-11 ed.2) 150 15
120
A05300
lightning current arrester for 3-phase TN-C system, installation at the entry into building / 75 kA (10/350 µs) / T1 (ČSN EN 61643-11 ed.2) 260 25