Part number
Manufacturer
Description
Stock
81
A03670
SALTEK
surge arrester for PV systems (both poles) / up to 1000 V DC, 40 kA (8/20 µs) / PV T2 (ČSN EN 50539-11)
In Stock
82
A03671
surge arrester for PV systems (both poles) / up to 1000 V DC, 40 kA (8/20 µs), remote fault signalling / PV T2 (ČSN EN 50539-11)
83
A03732
surge protection with RFI filter, installation close to protected equipment / 25 A / T3 (ČSN EN 61643-11 ed.2) 275 10
84
A03783
combination of lightning current and surge arrester for single-phase system TT, installation at the entry into building / 50 kA (10/350 µs), 100 kA (8/20 µs), remote fault signalling / T1,T2 (ČSN EN 61643-11 ed.2)
85
A03784
combination of lightning current and surge arrester for single-phase system TN-S, installation at the entry into building / 50 kA (10/350 µs), 120 kA (8/20 µs), remote fault signalling / T1,T2 (ČSN EN 61643-11 ed.2)
86
A03809
lightning current and surge arrester for single-phase system TN-S, installation at the entry into building / 25 kA (10/350 µs), 120 kA (8/20 µs) / T1,T2 (ČSN EN 61643-11 ed.2) 275 12,5 30
87
A04053
lightning current arrester for TN or TT system, installation at the entry into building / 50 kA (10/350 µs), voltage protection level 2.5 kV, replaceable module, remote fault signalling / T1 (ČSN EN 61643-11 ed.2) 255 50
88
A04054
lightning current arrester for TN or TT system, installation at the entry into building / 50 kA (10/350 µs), voltage protection level 2.5 kV, replaceable module / T1 (ČSN EN 61643-11 ed.2) 255 50
89
A04059
lightning current arrester and surge arrester for PV systems / up to 1000 V DC, 12.5 kA (10/350 µs) / PV T1, PV T2 (ČSN EN 50539-11)
90
A05091
combination of lightning current and surge arrester for systems TN and TT, installation at the entry into building / 25 kA (10/350 µs), 60 kA (8/20 µs) / T1,T2 (ČSN EN 61643-11 ed.2) 260 25 30
91
A05092
combination of lightning current and surge arrester for single-phase system TN-S, installation at the entry into building / 50 kA (10/350 µs), 120 kA (8/20 µs) / T1,T2 (ČSN EN 61643-11 ed.2) 260 25 30
92
A05093
combination of lightning current and surge arrester for three-phase system TN-C, installation at the entry into building / 75 kA (10/350 µs), 180 kA (8/20 µs) / T1,T2 (ČSN EN 61643-11 ed.2) 260 25 30
93
A05094
combination of lightning current and surge arrester for three-phase system TN-S, installation at the entry into building / 100 kA (10/350 µs), 240 kA (8/20 µs) / T1,T2 (ČSN EN 61643-11 ed.2) 260 25 30
94
A05095
combination of lightning current and surge arrester for single-phase system TT, installation at the entry into building / 50 kA (10/350 µs), 100 kA (8/20 µs) / T1,T2 (ČSN EN 61643-11 ed.2)
95
A05096
combination of lightning current and surge arrester for three-phase system TT, installation at the entry into building / 100 kA (10/350 µs), 100 kA (8/20 µs) / T1,T2 (ČSN EN 61643-11 ed.2)
96
A05129
surge protection for 2-core signalling networks, installation close to protected equipment, terminal block with screw terminals / 60 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
97
A05131
surge protection for two 1-core signalling networks, installation close to protected equipment, terminal block with screw terminals / 48 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
98
A05132
surge protection for 2-core floating signalling networks, installation close to protected equipment, terminal block with screw terminals / 6 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
99
A05133
surge protection for 2-core floating signalling networks, installation close to protected equipment, terminal block with screw terminals / 12 V DC, max. 0,5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012
100
A05134
surge protection for 2-core floating signalling networks, installation close to protected equipment, terminal block with screw terminals / 24 V DC, max. 0.5 A / D1, C2, C3 EN 61643-21+A1,A2:2013, IEC 61643-21+A1,A2:2012